Guide
DHA Karachi Plot Construction Rules: Setbacks, Coverage and Building Requirements

By Maham Imtiaz
Real Estate AnalystVerified author
13 min read
Buying a plot in DHA Karachi is only half the decision. The other half is what you can legally build on it: how much of the plot the house may cover, how far it must sit from the boundary, how high it can rise and what you can put on the roof. DHA Karachi sets these limits in its Building Control and Town Planning Regulations 2020, and every building plan must follow them. This guide turns those regulations into plain tables by plot size, so you can check whether a plot fits your plans before you buy.
The rules change with plot size, so start with the size you can afford. Browse the current plots for sale in DHA Karachi on Milkiyat, note each plot's exact area in square yards, and match it to the coverage and setback bands below.
Construction rules sit inside DHA Karachi's wider planning system of phases, roads and amenities. Milkiyat's complete DHA Karachi area guide covers that bigger picture. This page focuses on one practical question: what the regulations allow you to build on a residential plot.
Which Rules Apply in DHA Karachi?
The Pakistan Defence Officers Housing Authority (PDOHA) Karachi adopted the Building Control and Town Planning Regulations 2020 at a special Executive Board meeting on 19 August 2020. They replace all earlier DHA Karachi regulations and byelaws, and they apply across the whole area under PDOHA Karachi's jurisdiction.
| Item | Detail |
|---|---|
| Rules in force | PDOHA Building Control and Town Planning Regulations 2020 |
| Approved | Special Executive Board Meeting No. 2/2020, 19 August 2020 |
| Applies to | All areas under PDOHA Karachi's jurisdiction |
| Scrutiny | DHA Town Planning and Building Control (TP&BC) Directorate |
| Final approval | Cantonment Board Clifton (CBC) |
You can read the full text in DHA Karachi's published Building Control and Town Planning Regulations 2020. The tables in this guide summarise the residential chapter. Always check the current version with DHA before you design.
Coverage and Setbacks by Plot Size
The regulations group residential plots into four size bands. Each band sets a maximum covered area and the compulsory open space (COS), which is the setback that must stay open at the front, rear and side.
| Plot size band | Max covered area | Front COS | Rear COS | Side COS | Floors |
|---|---|---|---|---|---|
| Up to 200 sq yd | 90% | Not specified | Not specified | Not specified | Basement + ground + 1 |
| 201–400 sq yd | 75% | 5 ft | 3 ft | 5 ft (right side only) | Basement + ground + 1 |
| 401–700 sq yd | 65% | 10 ft | 5 ft | 5 ft | Basement + ground + 1 |
| 701 sq yd and above | 50% | 20 ft | 10 ft | 10 ft | Basement + ground + 1 |
Source: PDOHA Building Control and Town Planning Regulations 2020, Table 1.
Two details matter for larger plots. On 401–700 sq yd plots, a rear sub-divided plot needs only 5 ft of front COS. On 950–1,000 sq yd plots with a frontage of 64 ft or less, the side COS drops to 7 ft 6 in.
What Each Common Plot Size Allows
Here is what those bands mean for the four sizes buyers search most. The footprint figures assume the full allowed coverage on the ground floor.
| Plot size | Band | Coverage | Approx. ground-floor footprint |
|---|---|---|---|
| 125 sq yd (5 marla) | Up to 200 sq yd | 90% | About 1,010 sq ft |
| 250 sq yd (10 marla) | 201–400 sq yd | 75% | About 1,690 sq ft |
| 500 sq yd (1 kanal) | 401–700 sq yd | 65% | About 2,925 sq ft |
| 1,000 sq yd (2 kanal) | 701 sq yd and above | 50% | About 4,500 sq ft |
Footprint = plot size × 9 sq ft × coverage. Your architect and the approved plan set the final figures.
Notice the step at each band. A 500 sq yd plot is twice the size of a 250 sq yd plot, but it allows only about 1.7 times the footprint, because coverage drops from 75 to 65 percent. Buyers who want maximum built area per rupee often prefer plots near the top of a band rather than just above it.
Height Limits
The regulations set height ranges rather than a simple floor count, and they apply to all residential plots.
| Element | Minimum | Maximum |
|---|---|---|
| Plinth | 2 ft | 4 ft 6 in |
| Ground and first floor (internal height) | 9 ft 6 in | 15 ft |
| Main building to roof top | 22 ft | 32 ft |
| Main building with parapet, from road crown | 26 ft | 37 ft |
| Parapet on an accessible roof | 4 ft | 5 ft |
| Stair tower or water tank with slab | 7 ft 6 in | 10 ft |
| Overall height including stair tower | 30 ft | 45 ft |
| Basement ceiling height | 8 ft | — |
In practice, these limits allow a basement, a ground floor and one upper floor, with a stair tower on the roof.
Basements
Basements are allowed, but they carry conditions that affect both cost and neighbours.
| Rule | What it means |
|---|---|
| Size | Up to the allowed ground-floor footprint |
| Indemnity bond | Required before plan approval; owner pays for any damage to neighbours |
| Use | Parking allowed |
| Kitchen, toilet, bath | Kitchen only where COS or a light well applies; otherwise toilet and bath only |
| Sump pit | Must be designed and waterproofed |
| Walls next to existing houses | Must be completed within 45–60 days of starting excavation |
| Retaining walls | Must be reinforced concrete |
DHA also issues construction NOCs at key stages, including a foundation or basement-level NOC that verifies the basement area, its depth and the underground water tank.
Boundary Walls, Gates and Parking
Boundary walls cause frequent disputes, so the regulations fix their height precisely.
| Item | Rule |
|---|---|
| Boundary wall height | 8 ft to 10 ft from road crown |
| Extra protective barrier | Iron barrier up to 2 ft on top of the wall |
| Pet grill or railing | Up to 6 ft |
| Gate columns | No higher than the boundary wall |
| Stairs outside the wall | Not allowed, except a ramp and wicket-gate steps up to 4 ft |
| Car porch or garage | Required on plots of 401 sq yd and above, at least 10 ft × 14 ft |
If you are buying a finished home rather than a plot, check these items on site too. Many older houses among the current houses for sale in DHA Karachi carry walls, rooms or roof structures that may not match their approved plans.
Servant Quarters and Roof Rules
Servant quarters and roof structures are the most common source of violations. The regulations restrict both.
| Item | Rule |
|---|---|
| Servant quarter location | Must form part of the main building; not allowed in any COS |
| Servant quarter size | At least 80 sq ft, 8 ft wide, 9 ft 6 in clear height |
| Rear stair to servant room | Allowed on plots of 401 sq yd and above, with 3 ft from the boundary wall |
| Allowed on the roof | Stair tower, overhead water tank, solar systems, green roof, landscape elements |
| Not allowed in the stair tower | Living room, servant quarter or bathroom |
| Powder room | Up to 24 sq ft, inside the stair tower's allowed area |
| Mobile phone antennas | Not allowed on residential roofs |
Stair tower areas also have caps. A box-type stair tower may cover up to 275 sq ft on plots up to 700 sq yd and 325 sq ft on larger plots, with smaller caps for dogleg, straight and spiral stairs.
Courts enforce these limits. In a 2026 case, a resident asked the Sindh High Court to order the removal of a servant quarter, staircase and over-height boundary wall at a DHA Phase 1 house, alleging breaches of the 2020 Regulations. The case shows that neighbours can and do challenge non-compliant construction.
Rules for Corner Plots
Corner plots follow extra rules because they face two roads.
| Rule | Detail |
|---|---|
| Definition | A plot on at least two vehicular streets, with a chamfer |
| Chamfer at junctions of 60 ft roads or wider | 10 ft × 10 ft |
| Chamfer at other junctions | 6 ft × 6 ft |
| Two gates | Allowed if the side road is not a high-traffic road or khayaban |
| Second gate size | Wicket gate only below 300 sq yd; up to 12 ft from 300 sq yd; 15 ft from 500 sq yd; 20 ft from 1,000 sq yd |
| Main gate position | Not at or near the chamfer |
| Frontage | Set by the allotment or transfer letter |
Milkiyat's guide to corner plots vs normal plots in DHA Karachi explains how these rules affect usable space and price.
How Building Plan Approval Works
Every residential building in DHA Karachi needs an approved plan before work starts. DHA scrutinises the plan, forwards it to CBC and then the Military Estate Office (MEO), and CBC grants the final approval.
| Stage | What happens |
|---|---|
| 1. Site plan | Get the latest site plan for the plot from DHA |
| 2. Demarcation | Apply for demarcation and boundary wall permission |
| 3. Plan submission | Architect submits drawings at DHA's Central Control Cell |
| 4. Scrutiny | TP&BC Directorate checks the plan against the regulations |
| 5. Approval | Plan moves to CBC and MEO; CBC grants final approval |
| 6. Construction NOCs | Stage checks, including the basement or foundation level |
| 7. Completion plan | Built house must match the approved plan |
| Help along the way | Verified DHA Karachi property agents can recommend architects who know the process |
DHA Karachi allows two years of construction from the plan's sanction, with extensions available on application. A local agent who handles DHA properties can often recommend architects familiar with the TP&BC process.
Phase and Plot Type Differences
The 2020 Regulations apply across PDOHA Karachi's jurisdiction, but your phase still matters. Older phases have many houses built under earlier rules, and Milkiyat's DHA Karachi Phase 7 guide describes one established phase in detail.
Newer areas, by contrast, have more open plots that owners design from the start under the 2020 Regulations. That makes compliance simpler, because no earlier structure needs to be regularised.
Plots in any phase may also carry site-specific conditions in their site plans, such as a radius at a corner. The regulations say you must follow the site plan in those cases.
Apartment and commercial buildings follow separate chapters of the regulations, with different coverage, height and parking rules. If you would rather buy a finished unit than build, compare current apartments for sale in DHA Karachi and ask the seller for the building's approved and completion plans.
Checklist Before You Design
Run these checks with your architect before you buy or design.
| Check | Why |
|---|---|
| Exact plot area | Sets your coverage band and setbacks |
| Latest site plan | May carry plot-specific conditions |
| Corner or inner plot | Corner plots need chamfers and gate rules |
| Neighbouring buildings | Basement work must protect them |
| Planned roof use | Only listed roof structures are allowed |
| Approval timeline | Construction must finish within the allowed period |
For the full set of checks on ownership, dues and documents, read Milkiyat's DHA Karachi plot buying checklist.
Frequently Asked Questions
Q1. What are the construction rules for plots in DHA Karachi?
DHA Karachi follows the PDOHA Building Control and Town Planning Regulations 2020. They set coverage, setbacks, heights, basement rules, boundary walls and roof structures for every plot size band.
Q2. How much of a 500 sq yd plot can I cover in DHA Karachi?
A 500 sq yd plot falls in the 401–700 sq yd band, which allows 65 percent coverage, with 10 ft of front, 5 ft of rear and 5 ft of side open space. Most open 500 sq yd plots sit among current DHA Phase 8 listings.
Q3. How many floors can I build in DHA Karachi?
The regulations allow a basement, a ground floor and one upper floor on residential plots, with overall height including the stair tower capped at 45 ft.
Q4. What setbacks apply to a 1,000 sq yd plot?
Plots of 701 sq yd and above need 20 ft of front, 10 ft of rear and 10 ft of side open space, with 50 percent maximum coverage. Many large plots and bungalows appear among DHA Phase 6 listings.
Q5. Can I build a basement in DHA Karachi?
Yes. A basement may extend up to the allowed ground-floor footprint, but you must give an indemnity bond, protect neighbouring buildings and finish walls next to existing houses within 45–60 days of starting excavation.
Q6. Can I build a servant quarter on the roof?
No. Servant quarters must form part of the main building, and the regulations do not allow a servant quarter, living room or bathroom in the stair tower.
Q7. Who approves building plans in DHA Karachi?
DHA's Town Planning and Building Control Directorate scrutinises the plan and forwards it to CBC and the MEO. CBC grants the final approval.
Q8. Do the same rules apply to commercial plots?
No. Commercial buildings follow a separate chapter of the regulations, with their own coverage, height and parking rules. Compare commercial property for sale in DHA Karachi with that chapter in mind.
Sources
- DHA Karachi — Building Plan Approval Procedure
- Sindh High Court — Order on DHA Phase 1 Open-Space Construction under the 2020 Regulations
- Cantonment Board Clifton (CBC) — Official Website
Disclaimer: This guide summarises the residential provisions of the PDOHA Building Control and Town Planning Regulations 2020 as published by DHA Karachi, for general information only. Regulations, site-plan conditions and procedures may change, and individual plots can carry specific conditions. Before you design or build, confirm all requirements with DHA Karachi's TP&BC Directorate, the Cantonment Board Clifton and a registered architect. Milkiyat.com gives no guarantee of any approval or outcome, and this guide is not legal or professional advice.